VEGA VEGACAL 65 4 … 20 mA_HART - two-wire User Manual

Page 42

Advertising
background image

42

10 Supplement

VEGACAL 65 • 4 … 20 mA/HART - two-wire

30033-EN-130917

Ʋ VEGACAL 65 of 316L with cable PT-

FE partly insulated ø 6 mm (0.236 in)

-50 … +150 °C (-58 … +302 °F)

Ʋ with temperature adapter [option

with cable PTFE insulated ø 6 mm

(0.236 in)]

-50 … +200 °C (-58 … +392 °F)

1

2

3

-50°C

(-58°F)

50°C

(122°F)

40°C

(104°F)

-40°C

(-40°F)

80°C

(176°F)

0°C

(32°F)

100°C

(212°F)

150°C

(302°F)

200°C

(392°F)

Fig. 27: Ambient temperature - Process temperature
1 Process temperature

2 Ambient temperature

3 Temperature range with temperature adapter

Dielectric constant

≥ 1.5

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug

1)

Ʋ Single chamber housing

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5

or:

– 1 x closing cap M20 x 1.5; 1 x blind plug M20 x 1.5

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

– 1␣x plug (depending on the version), 1␣x blind stopper

M20␣x␣1.5

Ʋ Double chamber housing

– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5; 1 x blind plug M16 x 1.5 or

optionally available with 1 x plug M12 x 1 for external

display and adjustment unit

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, 1 x blind

plug M16 x 1.5 or optionally 1 x plug M12 x 1 for exter-

nal display and adjustment unit

or:

– 1 x plug (depending on the version), 1 x blind plug

M20 x 1.5; 1 x blind plug M16 x 1.5 or optionally avail-

able with 1 x plug M12 x 1 for external display and

adjustment unit

1)

Depending on the version M12 x 1, according to DIN 43650, Harting, 7/8" FF.