VEGA VEGAVIB 61 - Relay (DPDT) User Manual
Page 27
-
Max.
3 A AC, 1 A DC
Breaking capacity
-
Min.
50 mW
-
Max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
min./max.
Switching delay
-
When immersed
0.5 s
-
When laid bare
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of solids
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
6 bar
(87psi)
-50°C
(-58°F)
16 bar
(232psi)
50°C
(122°F)
100°C
(212°F)
0°C
(32°F)
150°C
(302°F)
200°C
(392°F)
250°C
(482°F)
1
2
Fig. 26: Process pressure - Process temperature
1
Process temperature
2
Process pressure
VEGAVIB
61 of 316L
-50 … +150 °C (-58 … +302 °F)
Process temperature (thread or flange tem-
perature) with temperature adapter (option)
-50 … +250 °C (-58 … +482 °F)
VEGAVIB
61 • - Relay (DPDT)
27
9 Supplement
29265
-
EN
-120418