9 Supplement
VEGACAP 62 • - contactless electronic switch
30005-EN-130916
Adjustment elements
Mode switch
Ʋ Min.
Min. detection or dry run protection
Ʋ Max.
Max. detection or overflow protection
DIL switch for measuring range selection
Ʋ range 1
0 … 20 pF
Ʋ range 2
0 … 85 pF
Ʋ range 3
0 … 450 pF
Potentiometer
Switching point adaptation
Voltage supply
Operating voltage
20 … 253 V AC, 50/60 Hz, 20 … 253 V DC
Domestic current requirement
approximately 3 mA (via load circuit)
Load current
Ʋ Min.
10 mA
Ʋ Max.
400 mA (at I > 300 mA the ambient temperature can be
max. 60 °C/140 °F) max. 4 A up to 40 ms
Electrical protective measures
Protection rating
IP 66/IP 67
Overvoltage category
III
Protection class
I
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be do
and "serial number search" as well as via "Downloads" and "Approvals".