VEGA VEGAVIB 65 - transistor output User Manual

Page 31

Advertising
background image

Adjustment elements
Mode switch
- min.

min. detection or dry run protection

- max.

max. detection or overfill protection

Voltage supply
Supply voltage

10 … 55 V DC

Power consumption

max. 0.5 W

Electrical protective measures
Protection
- Plastic housing

IP 66/IP 67

- Alu and stainless steel standard

IP 66/IP 68 (0.2 bar)

2)

- Alu and stainless housing, optionally

available

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

Approvals

3)

ATEX II 1/2G, 2G EExd d IIC T6
ATEX II 1/2 D IP66 T

2)

Requirement to maintain the protection is the suitable cable.

3)

Deviating data in Ex applications: see separate safety instructions.

Supplement

VEGAVIB 65 - with transistor output

31

29285

-EN

-060508