4 Mounting

Electronics module • VEGABAR series 50/60

30175-EN-130322

2

1

Fig. 3: Loosening the holding screws
1 Electronics module

2 Screws (2 pcs.)

5. Pull the previous electronics out with the opening levers.
Note:

Make sure that the housing is not rotated during the electronics ex-

change. Otherwise the plug may be in a different position later.
6. Insert the new electronics module carefully. Make sure that the

plug is in the correct position.

7. Screw in the two holding screws and tighten them
8. Connect the connection cables according to the operating in-

structions manual of the respective sensor

9. Screw the housing cover back on
The electronics exchange is now finished.