VEGA VEGASWING 63 - contactless electronic switch User Manual

Page 30

Advertising
background image

30

9 Supplement

VEGASWING 63 • - contactless electronic switch

29228-EN-130409

1

2

-50 °C

(-58 °F)

0 °C

(32 °F)

50 °C

(122 °F)

100 °C

(212 °F)

150 °C

(302 °F)

200 °C

(392 °F)

250 °C

(482 °F)

20

(290)

-1 (-14,5)

40

(580)

64

(928)

Fig. 35: Process temperature - Process pressure with switch position 0.5 g/cm³ (sensitivity switch)
1 Process pressure in bar (psig)

2 Process temperature in °C (°F)

Viscosity - dynamic

0.1 … 10000 mPa s (requirement: with density 1)

Flow velocity

max. 6 m/s (with a viscosity of 10000 mPa s)

Density

0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.5 … 2.5 g/cm³

(0.018 … 0.09 lbs/in³) by switching over

Electromechanical data
Cable entry/plug (dependent on the version)

Ʋ Single chamber housing

– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),

1 x blind plug M20 x 1.5; attached 1 x cable entry

M20 x 1.5

or:

– 1 x cable entry ½ NPT, 1 x blind plug ½ NPT, 1 x cable

entry ½ NPT

or:

– 1 x plug M12 x 1; 1 x blind plug M20 x 1.5

Screw terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Adjustment elements
Mode switch

Ʋ A

Max. detection or overflow/overfill protection

Ʋ B

Min. detection or dry run protection

Density changeover switch

Ʋ 0.5

0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)

Ʋ 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Voltage supply
Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 253 V DC

Domestic current requirement

approximately 3 mA (via load circuit)

Load current

Ʋ Min.

10 mA

Advertising