6 set up, 1 general information, 2 adjustment elements – VEGA VEGAVIB 61 - two-wire User Manual

Page 20: 6set up

Advertising
background image

6

Set up

6

.1 General information

The figures in brackets refer to the following illustrations.

On the electronics module you will find the following indicating and
adjustment elements:

l

Potentiometer for adaptation to the product density (1)

l

DIL switch for mode adjustment - min./max. (2)

l

Signal lamp (5)

Note:
As a rule, always set the mode before starting to set up VEGAVIB 61 .
If used on a VEGATOR signal conditioning instrument, always set the
mode switch (2) on VEGAVIB 61 to max. mode.

The mode is selected on the signal conditioning instrument with the
mode switch.

The switching output will change if you set one of the two mode
switches afterwards. This could possibly trigger other connected
instruments or devices.

6

.2 Adjustment elements

3

4

1

2

5

Fig. 12: Electronics and connection compartment - two-wire output

1

Potentiometer for switching point adaptation

2

DIL switch for mode adjustment

3

Ground terminal

4

Connection terminals

5

Control lamp

Function/Configuration

Electronics and connec-
tion compartment

20

VEGAVIB

61 • - two-wire

6 Set up

29268

-EN

-120418

Advertising