3 Product description

VEGACAL 62 • Foundation Fieldbus

30026-EN-130917

1

2

3

Fig. 3: Functional principle - Plate capacitor
1 Distance between the electrode surfaces

2 Size of the electrode surfaces

3 Type of dielectric between the electrodes

The probe and the vessel wall are the capacitor plates. The measured

product is the dielectric. Due to the higher dielectric constant of the

product compared to air, the capacitance increases as the probe is

gradually covered.
The capacitance as well as the resistance change are converted by

the electronics module into a level-proportional signal.

Power is supplied via the H1 Fieldbus. A two-wire cable according to

Fieldbus specification serves as carrier of both power and digital data

for multiple sensors. This cable can be operated in two versions:

via an H1 interface card in the control system and additional power

supply

via a Linking device with HSE (High speed Ethernet) and addi-

tional power supply according to IEC 61158-2

The DD (Device Descriptions) and CFF (capability files) necessary

for planning and configuration of your FF (Foundation Fieldbus) com-

munication network are available in the download area of the VEGA

homepage www.vega.com under "Services - Downloads - Software

- Foundation Fieldbus". The appropriate certificates are also available

there. A CD with the appropriate files and certificates can be ordered

via e-mail under [email protected] or by phone from one of the

VEGA agencies under the order number "DRIVER.S".
The backlight of the display and adjustment module is powered by the

sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specified in chapter "Technical data".
The optional heating requires its own operating voltage. You can find

details in the supplementary instructions manual "Heating for display

and adjustment module".
This function is generally not available for approved instruments.

3.3 Operation

The instrument can be adjusted with the following adjustment media:

Power supply and bus

communication

DD/CFF

Advertising