2 principle of operation, 3 operation – VEGA VEGAFLEX 65 4 … 20 mA_HART four-wire User Manual

Page 8

Advertising
background image

l

S

erial number

l

T

echnical data

l

A

rticle numbers, documentation

l

SIL

identification (with SIL rating ex works)

W

ith the serial number, you can access the delivery data of the

instrument via www.vega.com, "VEGA Tools" and "serial number
search
". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.

3

.2 Principle of operation

VEGAFLEX

65

is a level sensor with pipe probe for continuous level

measurement.

I

t is designed for industrial use in all areas of process technology and

can be used in liquids.

H

igh frequency microwave pulses are guided along a steel rope or a

rod. Upon reaching the product surface, the microwave pulses are
reflected. The running time is evaluated by the instrument and
outputted as distance.

F

our-wire electronics with separate power supply.

T

he supply voltage range can differ depending on the instrument

version.

T

he data for power supply are specified in chapter "Technical data".

M

easured value transmission is carried out via the 4 … 20 mA/HART

output separate from power supply.

T

he background lighting of the indicating and adjustment module is

powered by the sensor. A certain level of operating voltage is required
for this. You can find the exact voltage specifications in chapter
"T

echnical data".

3

.3 Operation

T

he instrument can be adjusted with the following adjustment media:

l

W

ith indicating and adjustment module

l

with the suitable VEGA DTM in conjunction with an adjustment
software according to the FDT/DTM standard, e.g. PACTware and
PC

l

with manufacturer-specific adjustment programs AMS™ or PDM

l

W

ith a HART handheld

Application range

Functional principle

Voltage supply

8

VEGAFLEX

65 • 4 … 20

mA/HART - four-wire

3 P

roduct description

31846

-EN

-120329

Advertising