2 mounting, 2mounting – VEGA VEGAFLEX 66 Spacer Rod-ø 6 mm _ Rod-ø 16 mm User Manual
Page 3
2
Mounting
2
2
1
Fig. 1: Mounting of the spacer
1
Spacer
2
Retaining ring
1
Measure the diameter of the standpipe or bypass tube and adapt
the spacers accordingly. The markings on the 4-leg spacer ensure
a simple tailoring to the tube diameter DN 50 (2") and DN 80 (3").
For cutting, use a metal saw or strong pliers.
2
The spacer should be mounted to the lower edge of the probe rod.
If several spacers are necessary, you should mount them at a
distance of approx. 2.50 m (8 ft). Determine where the spacer
should placed and mark the position.
3
Slide the retaining ring (2) to the rod of the probe.
Tip:
Wear gloves when sliding the parts to the rod or use a thin tube section
4
Slide the spacer (1) and another retaining ring (2) to the rod of the
probe.
The retaining rings fix the spacer in the requested position.
Spacer • Rod-ø 6 mm / Rod-ø 16 mm
3
2 Mounting
30391
-
EN
-100527