VEGA VEGAFLEX 67 (-200…+400°C) 4 … 20 mA_HART two-wire User Manual

Page 56

Advertising
background image

1000

750

500

250

14

18

16

20

22

24

26

28

30

32

34

36

V

4

1

2

3

Fig. 31: Voltage diagram

1

HART load

2

Voltage limit EEx-ia instrument

3

Voltage limit non-Ex/Ex-d instrument

4

Operating voltage

Electrical protective measures

P

rotection, depending on housing version

-

P

lastic housing

IP

66/IP 67

-

A

luminium housing, stainless steel

housing - investment casting, stainless
steel housing - electro-polished

IP

66/IP 68 (0.2

bar)

4)

-

A

luminium and stainless housing, in-

vestment casting (optionally available)

IP

66/IP 68 (1

bar)

O

vervoltage category

III

P

rotection class

II

Approvals

I

nstruments with approvals can have different technical data depending on the version.

T

hat's why the associated approval documents have to be noted with these instruments. They are

part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial
number search
" as well as via "Downloads" and "Approvals".

4)

A

suitable cable is the prerequisite for maintaining the protection rating.

56

VEGAFLEX

67 • 4 … 20

mA/HART - two-wire

10 S

upplement

32311

-EN

-120329

Advertising