2 mounting instructions – VEGA EL 3 Conductive probe User Manual

Page 10

Advertising
background image

4

.2 Mounting instructions

Due to agitators, equipment vibration or similar, the level switch can be
subjected to strong lateral forces.

Extreme vibration caused by the system, e.g. due to agitators or
turbulence in the vessel from fluidization, can cause the probe of EL 3
to vibrate in resonance. If a longer rod version is necessary, you can
secure the probe by fastening a suitable insulating brace or guy
directly above the end of the rod.

1

2

1

2

Fig. 3: Fasten the probe

1

Probe

2

Plastic sleeve at the probe end or laterally mounted

If EL 3 is mounted in the filling stream, unwanted false measurement
signals can be generated. For this reason, mount EL 3 at a position in
the vessel where no disturbances, e.g. from filling openings, agitators,
etc., can occur.

This applies particularly to instrument versions with a longer probe.

Agitators and fluidiza-
tion

Inflowing medium

10

Conductive probe EL 3

4 Mounting

32652

-EN

-100208

Advertising