VEGA VEGAFLEX 62 4 … 20 mA_HART four-wire User Manual

Page 13

Advertising
background image

≥ 300 mm (11

13

/

16

")

150 mm (5

29

/

32

")

150mm (5

29

/

32

")

1

SW 13

L

Fig. 3: Bow-shaped segment ø 16 mm (0.63 in)

1

Max. filling height

L

150 mm (5.91 in)

B

efore beginning the welding work, remove the electronics module

from the sensor. By doing this, you avoid damage to the electronics
through inductive coupling.

W

ith threaded versions, the housing must not be used to screw in the

instrument! Applying tightening forces on the housing can damage its
internal parts.

U

se the hexagon for screwing in.

U

se the recommended cables (see chapter "Connecting to power

supply") and tighten the cable gland.

Y

ou can give your instrument additional protection against moisture

penetration by leading the connection cable downward in front of the
cable entry. Rain and condensation water can thus drain off. This
applies mainly to outdoor mounting as well as installation in areas
where high humidity is expected (e.g. through cleaning processes) or
on cooled or heated vessels.

Welding work

Handling

Moisture

VEGAFLEX

62 • 4 … 20

mA/HART four-wire

13

4 M

ounting

31838

-

EN

-100426

Advertising