20˚

Fig. 3: Horizontal installation

a

Protective sheet

b

Concave protective sheet for abrasive solids

If VEGAVIB 65 is mounted in the filling stream, unwanted

switching signals may be generated. Mount VEGAVIB 65 at a

location in the vessel where no disturbing influence from e.g.

filling openings, agitators etc. can occur.

To minimise flow resistance caused by the tuning fork,

VEGAVIB 65 should be mounted in such a way that the

surfaces of the fork are parallel to the product movement.

1

2

Fig. 4: Orientation of the tuning fork in case of flow

1

Marking with screwed version

2

Direction of flow

Inflowing material

Flow

VEGAVIB 65 - with NAMUR output