VEGA VEGAPULS 68 Antenna extension User Manual
Page 8
1
2
Fig. 5: Position of the polarisation markings with flange version
1
Markings for the polarisation plane
2
Rinsing air connection
3
Fasten antenna extension with screws on the radar sensor
4
Make sure that antenna extension and radar sensor are
assembled gap free
5
Tighten screws crosswise, torque max. 2.5 Nm (1.844 lbf ft)
Assembly is finished.
3.4 M
ounting steps, multi-sectional antenna
extension
With multi-sectional antenna extensions, the antenna system consists
of upper part, middle part and antenna. The parts are shipped
dismounted and must be reassembled on site.
Proceed as follows:
1
Remove conical protective cover from radar sensor
2
Assemble radar sensor and individual parts of the antenna
extension in such a way that the respective markings for the
polarisation plane as well as the optional rinsing air connection are
aligned with each other
8
Antenna extension • for VEGAPULS 62 and 68
3 Mounting
34082
-EN
-110616