2

Fig. 5: Position of the polarisation markings with flange version

1

Markings for the polarisation plane

2

Rinsing air connection

3

Fasten antenna extension with screws on the radar sensor

4

Make sure that antenna extension and radar sensor are
assembled gap free

5

Tighten screws crosswise, torque max. 2.5 Nm (1.844 lbf ft)

Assembly is finished.

3.4 M

ounting steps, multi-sectional antenna

extension

With multi-sectional antenna extensions, the antenna system consists
of upper part, middle part and antenna. The parts are shipped
dismounted and must be reassembled on site.

Proceed as follows:

1

Remove conical protective cover from radar sensor

2

Assemble radar sensor and individual parts of the antenna
extension in such a way that the respective markings for the
polarisation plane as well as the optional rinsing air connection are
aligned with each other