9 supplement, 1 technical data, 9supplement – VEGA EL 8 Conductive probe User Manual

Page 18

Advertising
background image

9

Supplement

9

.1 Technical data

General data

Materials 316Ti corresponds to 1.4571, 316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting

1.4301

-

Process seal

Klingersil C-4400

-

insulation (partly insulated)

PE

-

Electrode (rod partly PE insulated:
ø

4 mm/0.157 in)

316Ti

Materials, non-wetted parts

-

Housing

EPDM

Process fitting

G½ A (ISO 228 T1)

Weight

-

with basic weight

100 g (3.5 oz)

-

Rod weight: ø 4 mm (0.157 in)

100 g/m (1.1 oz/ft)

Sensor length (L)

0.03 … 1 m (0.1 … 3.3 ft)

Insulation length

27 mm (1.06 in)

Output variable

Suitable signal conditioning instruments

VEGATOR 256C, 532, 631

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Process pressure

-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psig)

Process temperature EL 8 of 316L

-10 … +60 °C (+14 … +140 °F)

Conductive of the medium

min. 7.5 µS/cm

Electrical protective measures

Protection rating

IP 50

18

Conductive probe EL 8

9 Supplement

32655

-EN

-100208