.1 Technical data

General data

Materials 316Ti corresponds to 1.4571, 316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting

316L

-

Process seal

Klingersil C-4400

-

insulation (partly insulated)

PTFE

-

Electrode (rod, PTFE partly insulated)

316Ti, Hastelloy C4 (2.4610)

Materials, non-wetted parts

-

Housing

316Ti

-

Housing cover

PBT

-

Seal between housing and housing
cover

NBR

-

Cable gland

brass, nickel-plated

Process fitting

G½ A (ISO 228 T1)

Weight

-

with stainless steel housing

400 g (14 oz)

-

Rod weight: ø 8 mm (0.315 in)

400 g/m (4.3 oz/ft)

Sensor length (L)

-

Stainless steel (316Ti)

0.04 … 4 m (0.131 … 13.12 ft)

-

Hastelloy C4 (2.4610)

0.05 … 4 m (0.164 … 13.12 ft)

Insulation length (L1)

0.039 … 0.2 m (0.128 … 0.656 ft)

Output variable

Suitable signal conditioning instruments

VEGATOR 256C, 532, 631

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Process pressure

-1 … 63 bar/-100 … 6300 kPa (-14.5 … 914 psig)

Process temperature EL 1 of 316L

-50 … +130 °C (-58 … +266 °F)

Conductive of the medium

min. 7.5 µS/cm

Electromechanical data

Cable entry

1 x cable gland M16 x 1.5 (cable: ø 5 … 10 mm/
0.2 … 0.35 in)

Conductive probe EL 1