3

Mounting

3

.

1

Mounting instructions

For mounting, a spanner with SW (spanner width) 11 and 13 is
required.

The sensor housings have two filter elements. The upper one near the
cable glands is used to ventilate the electronics housing. The lower
filter element in the area of the base is used to ventilate the measuring
cell.

The external ventilation is generally used for the lower filter element.
The following illustration shows the mounting location.

3

2

1

1

Fig. 2: Mounting location for the external ventilation with single and double
chamber housing
1

Mounting location of the external ventilation

2

Aluminium single chamber housing

3

Aluminium double chamber housing

3

.

2

Mounting steps

Proceed as follows:

1

Loosen, unscrew and remove the plastic protective cover with
spanner SW 11.

The protective cover is no longer required. Filter and O-ring must
remain in the opening. The opening must be free of dirt.

2

Screw the external ventilation manually into the thread. Tighten
with spanner SW 13.

Max. torque see chapter "Technical data".