11 Supplement

VEGAPULS 62 standpipe version • 4 … 20 mA/HART - four-wire

36508-EN-121011

Seal

Antenna impedance

cone

Process temperature (measured on the process

fitting)

FFKM (Kalrez 6375)

PFFE

-20 … +200 °C (-4 … +392 °F)

FFKM (Kalrez 2035)

PFFE

-15 … +200 °C (5 … +392 °F)

FFKM (Kalrez 6230)

PFFE

-15 … +200 °C (5 … +392 °F)

Vessel pressure relating to the antenna

system

-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psi)

Vessel pressure relating to the flange

nominal stage

see supplementary instructions manual "Flanges ac-

cording to DIN-EN-ASME-JIS"

Vibration resistance

1 g at 5 … 200 Hz according to EN60068-2-6 (vibration

with resonance)

Shock resistance

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry

Ʋ Cable gland

M20 x 1.5 (cable: ø 5 … 9 mm)

Ʋ Cable entry

½ NPT

Ʋ Blind stopper

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Signal circuit

M12 x 1, according to ISO 4400, Harting HAN, 7/8" FF

Ʋ Indication circuit

M12 x 1

Wire cross-section (spring-loaded terminals)

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

Indicating and adjustment module
Voltage supply and data transmission

through the sensor

Indication

LC display in dot matrix

Measured value indication

Ʋ Number of digits

5

Ʋ Size of digits

W x H = 7 x 13 mm

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the sensor without cover IP 40

Materials

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

Integrated clock
Date format

Day.Month.Year