Proceed as follows:
1
Switch off power supply
2
Unscrew housing cover of the electronics compartment
3
Remove the terminal blocks according to the operating instruc-
tions manual of the respective sensor
4
Loosen the two holding screws with a screwdriver (Torx size T 10
or Phillips size 4)
2
1
5
6
7
8
1
2
+
( )
(-)
Fig. 3: Loosening the holding screws
1
Electronics module
2
Screws (2 pcs.)
5
Pull the previous electronics out by using the pull-out tool.
6
Insert the new electronics module carefully.
7
Insert the two hold screws and tighten them
8
Attach the terminal blocks according to the operating instructions
manual of the respective sensor
9
Screw the housing cover on
The electronics exchange is now finished.