VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire User Manual

Page 65

Advertising
background image

65

11 Supplement

VEGAPULS 67 • 4 … 20 mA/HART - two-wire

36531-EN-121011

Step response time

2)

≤ 3 s

Tracking speed of the measuring window

max.

1 m/min

Beam angle

3)

10°

Emitted HF power (depending on the parameter adjustment)

4)

Ʋ Average spectral transmission power

density

-14 dBm/MHz EIRP

Ʋ Max. spectral transmission power

density

+43 dBm/50 MHz EIRP

Ʋ Max. power density in a distance of

1 m

< 1 µW/cm²

Ambient conditions
Ambient, storage and transport tempera-

ture

-40 … +80 °C (-40 … +176 °F)

Process conditions
Process temperature (measured on the

process fitting)

-40 … +80 °C (-40 … +176 °F)

Vessel pressure

-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)

Vessel pressure - version with adapter

flange from DN 150 PP

-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)

Vibration resistance

5)

Ʋ Plastic horn antenna with compres-

sion or adapter flange

mechanical vibrations up to 2 g in the frequency range

5 … 200 Hz

Ʋ Plastic horn antenna with mounting

strap

mechanical vibrations up to 1 g in the frequency range

5 … 200 Hz

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry

Ʋ Cable gland

M20 x 1.5 (cable: ø 5 … 9 mm)

Ʋ Cable entry

½ NPT

Ʋ Blind stopper

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Signal circuit

M12 x 1, according to ISO 4400, Harting HAN, 7/8" FF

Ʋ Indication circuit

M12 x 1

Wire cross-section (spring-loaded terminals)

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

2)

Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk

solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2).

3)

Outside the specified beam angle, the energy of the radar signal has a level which is reduced by 50 % (-3 dB)

4)

EIRP: Equivalent Isotropic Radiated Power

5)

Tested according to the guidelines of German Lloyd, GL directive 2.

Advertising