VEGA VEGAFLEX 86 4 … 20 mA_HART two-wire User Manual

Page 90

Advertising
background image

90

11 Supplement

VEGAFLEX 86 • 4 … 20 mA/HART two-wire

41844-EN-130612

2

1

-100°C

(-148°F)

-200°C

(-328°F)

100 bar

(1450 psig)

200 bar

(2900 psig)

300 bar

(4350 psig)

400 bar

(5800 psig)

380 bar

(5510 psig)

350 bar

(5070 psig)

0°C

(32°F)

200°C

(392°F)

100°C

(212°F)

400°C

(752°F)

300°C

(572°F)

320 bar

(4640 psig)

450°C

(842°F)

Fig. 57: Process pressure - process temperature (version -196 … +450 °C/-321 … +842 °F)
1 Process temperature (depending on the seal material)

2 Process pressure

Vibration resistance

Ʋ Instrument housing

4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Ʋ Rod probe

1 g with 5 … 200 Hz according EN 60068-2-6 (vibration

at resonance) with rod length 50 cm (19.69 in)

Shock resistance

Ʋ Instrument housing

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Ʋ Rod probe

25 g, 6 ms according to EN 60068-2-27 (mechanical

shock) with rod length 50 cm (19.69 in)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry

Ʋ Cable gland

M20 x 1.5

Ʋ Cable diameter (options)

5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)

Ʋ Cable entry

½ NPT

Ʋ Blind plug

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Signal circuit

Plug M12 x 1, according to ISO 4400, Harting HAN,

7/8" FF

Ʋ Indication circuit

M12 x 1 plug

Wire cross-section (spring-loaded terminals)

Advertising