4 Mounting

Electronics module • VEGABAR series 80

45054-EN-131119

4 Mounting

4.1 General instructions

The pressure transmitters of series VEGABAR 80 are provided with a

double section electronics:

Measuring cell electronics

Processing electronics (electronics module)

The measuring cell electronics is located in the process fitting. It is not

accessible to the user.
The electronics module is located in the sensor housing and can be

exchanged by the user in case of a defect.

If no electronics module is available on site, it can be ordered from

the VEGA agency serving you. The order is possible without or with

sensor serial number. The serial number is stated on the type label of

the instrument or on the delivery note.
Without serial number

The electronics module without serial number contains no order-

specific data. However, operation of VEGABAR is also ensured

without these data. This allows the stocking of a "universal electronics

module" for multiple VEGABAR sensors of different types.
With serial number

The electronics module with sensor serial number contains order-

specific data such as housing material, process fitting, measuring cell

seal, etc.

Warning:

Switch off voltage supply before starting the mounting procedure. The

replacement electronics must only be mounted in idle condition.

Non-observance will damage the electronics!

The safety-relevant data for explosion protection of the electronics

module supplied later can deviate from the data of the previously

installed electronics module. If the electronics module supplied later

is installed in a certified, explosion-protected sensor, it is absolutely

necessary to observe the instrument "Safety instructions" attached to

the supplied electronics module! The attached label must be applied

on the sensor housing.

4.2 Mounting preparations

The electronics modules differ in their signal output, e.g. 4 … 20 mA/

HART.
There is another difference in the version "Standard" or "Climate com-

pensated". The version "Climate compensated" can be recognized by

the additional specification "climate compensated" on the type label

of the electronics module.
Note:

Make sure that you are using the correct version of the electronics

module. Otherwise, the air pressure compensation or the measure-

Measuring cell and pro-

cessing electronics

Sensor serial number

Assignment