2 wiring plan – VEGA VEGABAR 81 Modbus and Levelmaster protocol - Quick setup guide User Manual

Page 10

Advertising
background image

10

4 Connecting to power supply and bus system

VEGABAR 81 • Modbus and Levelmaster protocol

46304-EN-131125

6. Check the hold of the wires in the terminals by lightly pulling on

them

7. Connect the screen to the internal ground terminal, connect the

outer ground terminal to potential equalisation in case of power

supply via low voltage

8. Connect the lead cable for power supply in the same way accord-

ing to the wiring plan, in addition connect the ground conductor to

the inner ground terminal when powered with mains voltage.

9. Tighten the compression nut of the cable glands. The seal ring

must completely encircle the cables

10. Screw the housing cover back on
The electrical connection is finished.
Information:

The terminal blocks are pluggable and can be removed from the

housing insert. To do this, lift the terminal block with a small screwdriv-

er and pull it out. When inserting the terminal block again, you should

hear it snap in.

4.2 Wiring plan

2

1

Fig. 4: Position of connection compartment (Modbus electronics) and electron-

ics compartment (sensor electronics)
1 Terminal compartment

2 Electronics compartment

+

+

power supply

MODBUS

D0

D1

IS GND

USB

1

2

4

3

1

3 4 5

2

off on

( )

(

)

(-)

(-)

Fig. 5: Terminal compartment
1 USB interface

2 Slide switch for integrated termination resistor (120 Ω)

3 Voltage supply

4 Modbus signal

Overview

Terminal compartment

Advertising