7. Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1]

on Circuit Board A (Fig. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured
cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 6).

For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).

For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 6).

The total cable distance must not exceed 750 ft. for video transmission between the HubSat8D and each camera.
Repeat this step for all other camera channels [PVD2-4] on Circuit Board A and [PVD1-4] on Circuit Board B.

8. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) power

LEDs (Green) of the HubSat8D will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv
or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6).

9. Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to

each camera to insure proper operation and avoid possible damage.

10. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
11. Connect power outputs of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs

of cameras (Figs. 2a-2d, pg. 6). Polarity must be observed.

HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 6).

HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 6).

12. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners

to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed.
When using fixed cameras disregard this step.

13. Connect the BNC connector of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the

BNC video outputs of cameras (Figs. 2b-2d, pg. 6).

14. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6).
15. The power LEDs (Green) of the HubSat8D will illuminate when AC power is present (Fig. 1e, pg. 4).

Note: If any of the power LEDs are not illuminated the cause may be due to the following:
a.

AC mains fail.

b.

Illuminated master power disconnect circuit breaker is tripped.

c.

One or both primary in-line fuse(s) are blown.
Note: Replace fuse with same type and rating:
Primary in-line fuses are rated @ 3.5A/250V (Fig. 4b, pg. 6).

d. An individual power output voltage switch is set to the OFF position (Fig. 1d, pg. 4).
e.

A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.
To reset the PTC:
1.

Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must
remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 1d, pg. 4).

2.

Eliminate the trouble condition (short circuit or overload).

3.

Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 1d, pg. 4).

HubSat8D for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.
After completing steps 1-4 of Installation Instructions HubSat8D Passive UTP Transceiver Hub with Integral Camera
Power. proceed with the following.
1. For fixed cameras run two (2) CAT-5 cables between HubSat8D and HubWay, HubWayLD or HubWayLDH to allow

video transmission of up to eight (8) cameras. For PTZs run three (3) CAT-5 cables between HubSat8D and
HubWay, HubWayLD or HubWayLDH (Fig. 6, pg. 7).
a.

Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on Circuit Board A. Connect the
opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or
HubWayLDH unit (Fig. 6, pg. 7).

b.

Connect the second CAT-5 cable to the RJ45 jack marked [Video 1-4] on Circuit Board B. Connect the
opposite end of this CAT-5 cable into the RJ45 jack marked [CH 5-8] of HubWay, HubWayLD or
HubWayLDH unit (Fig. 6, pg. 7).

c.

For data (PTZ) connect the third CAT-5 cable to the RJ45 jack marked [Data 1-4] on Circuit Board A. Connect
the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or
HubWayLDH unit (Fig. 6, pg. 7).

Note: Data inputs of HubWay, HubWayLD or HubWa

yLDH units must be wired in parallel for proper operation.

When using fixed cameras disregard this step.