Altronix RBTUL Data Sheet User Manual

Rbtul relay module, Overview specifications, Agency approvals

Advertising
background image

Sensitive and ultra sensitive UL Listed relay module.

RBTUL
Relay Module

Rev. DSRBTUL_11192012

Overview

Specifications

UL Listed Burglar Alarm System
Accessory (UL 365).

Agency Approvals

Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com

ST1 Mechanical Drawing

Board Dimensions (L x W x H approx.):

2.75” (69.85mm) x 2” (50.8mm) x 1.25” (31.75mm)

Mounting Diagram

RBTUL

Input Voltage:

• 12VDC to 24VDC selectable operation.
• Current draw: 30mA.

Contact Rating:

• 1 amp/28VDC SPDT contacts.

Electrical:

• Operating temperature: -- 25º C to 55º C ambient.
• System AC input VA requirement: 7.2A.

Mechanical:

• DIN Rail mountable (Altronix model # ST1
Snap Track included).
• Dimensions (L x W x H approx.):
2.75” (69.85mm) x 2” (50.8mm)
x 1.25” (31.75mm).
• Product weight (approx.): 0.48 lbs. (0.22 kg).
• Shipping weight (approx.): 0.5 lbs. (0.23 kg).

DETAIL A

SEE

DETAIL A

.005

.002

.062

REF

2.875

Bottom

Side

Top

Side

3.00

.062

.078

.187

+ .010

2.720

+ .020

1.500

.219 + .010

.250 + .005

.031 + .004

.234 + .010

1.000 + .015

.640 + .015

2.75"

69.85mm

2.0"

50.8mm

1.39"

35.3mm

0.84"

21.3mm

Ø0.156"

3.96mm

Advertising