RBR1224 - Electronic Toggle/Ratchet Relay

Specifications:

• 12VDC to 24VDC operation.
• Positive (+) or negative (-) ultra sensitive trigger

(3VDC to 24VDC @ 20mA minimum).

• DPDT contacts rated at

2 amp/120VAC/28VDC.

• Relay status LED.
• Remote LED status output.
• Snap track mountable (order part # ST3).
Board dimensions: 3"L x 2.5"W x 1"H

Applications:

• Use with PGM alarm control panel outputs.
• Electronically shunt-alarm zones,

door control or keypads.

• Interfaces with wireless receivers.
• Converts momentary to maintained contacts.

Installation Instructions:

1. Connect aux power to terminals marked [POS (+)] and [NEG (-)].
2. The relay will change state to latch ON or OFF by the application of a positive

momentary trigger voltage to the terminals marked [TRG +] and [POS (+)] or negative
momentary trigger voltage to terminals marked [TRG -] and [NEG (-)].

3. Relay status LED is lit when relay is energized. To use a remote LED. Connect negative

lead of remoted LED, to terminal marked [LED] connect positive lead of LED to [POS (+)].

LED

TRG --

NEG (-- )

C

NO

NC

NC

NO

C

POS (+)

TRG +