Overview:

OLS75 power supply/charger converts 115VAC, 60Hz or 230VAC, 50Hz input, into a 12VDC or 24VDC @ 2.5 amps
of continuous supply current (see specifications). This general purpose power supply has a wide range of application for
access control and security system accessories that require additional power.

Specifications:

Voltage Output Selection Table:

Output VDC

Switch Position

Max. Load DC

12VDC

SW 1 - Closed

2.5 amp

24VDC

SW1 - Open

2.5 amp

Installation Instructions:

The OLS75 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Mount the OLS75 in the desired location/enclosure.
2. Slide [Power ON/OFF] switch to OFF position.
3. Set the OLS75 to the desired DC output voltage via SW1 (Voltage Output Selection Table).
4. Connect AC power to the terminals marked [L & N], connect ground to the terminal marked [G].

Use 18 AWG or larger for all power connections (Battery, DC output).

Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting).

5. Slide [Power ON/OFF] switch to ON position.
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
7. Slide [Power ON/OFF] switch to OFF position.
8. Connect devices to be powered to the terminals marked [– DC +].
9. When the use of stand-by batteries is desired, they must be lead acid or gel type.

Connect battery to the terminals marked [-- BAT +] (battery leads included).

Use two (2) 12VDC batteries connected in series for 24VDC operation.

10. When batteries are not used, a loss of AC will result in the loss of output voltage.
11. Connect appropriate signaling notification devices to AC Fail & Low battery supervisory

relay outputs marked [NC, C, NO].

12. Slide [Power ON/OFF] switch to ON position.

OLS75 - Offline Power Supply/Charger

Input:

• Universal input 115VAC, 50/60Hz, 0.95 amp
or 230VAC, 50/60Hz, 0.6 amp.

Output:

• 12VDC or 24VDC selectable output.
• 2.5 amp continuous supply current.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.

Battery Backup:

• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switch over to stand-by battery when AC fails.
• Maximum charge current 0.5 amp.
• Battery leads included.

Supervision:

• AC fail supervision (form “C” contacts).
• Low battery supervision (form “C” contacts).

Visual Indicators:

• AC input and DC output LED indicators.

Electrical:

• Operating temperature: --- 20º C to 49º C ambient.
• BTU/Hr.: 12VDC: 15.35 BTU/Hr. 24VDC: 30.7 BTU/Hr.
• System AC input VA requirement:
115VAC: 109.25VA. 230VAC: 138VA.

Features:

• Power ON/OFF switch.

Mechanical:

• Board Dimensions (approx. L x W x H):
7.25” x 4.5” x 1.75” (183.9mm x 114.52mm x 44.45mm)