Altronix DL1 Installation Instructions User Manual

Dl1_s, Dl1 - door control timer

Advertising
background image

DL1 - Door Control Timer

Specifications:

• 12 volt - 24 volt AC or DC operation.
• Dry relay output (1 form “C” contact, rated @ 2 amp).
• Isolated AC or DC voltage 5V-24V trigger.
• Time adjustable from 1 second to 1 minute.
• 12VDC regulated beeper output.
• Momentary or maintained trigger.
Board dimensions: 4"L x 1.5"W x .75"H

Installation Instructions:

1. Unit operates from 12-24 volts AC or DC. Voltage source should be connected to the terminals marked [AC].

When using DC power, polarity does not have to be observed.

2. Use form [C] relay contacts to operate desired device (magnetic lock, door strike, etc.). During normal

operation [C] contact is connected to [NC] and transfers to [NO] when timing cycle is initiated.

3. Adjust desirable time. By turning timing potentiometer clockwise you increase duration of the output.
4. Connect trigger voltage source to both terminals marked [TRG].
5. A surge suppressor should be used to eliminate RMI that is generated when electrical coil is being powered

down. It is recommended to use a diode in parallel with every DC coil magnet,
(Banded end of diode connected to positive terminal of coil or magnet).

DL1_S

DOOR TIMER

A

L

T

R

O

N

IX

C

O

R

P

.

B

K

L

Y

N

,

N

Y

1

1

2

2

0

M

A

D

E

IN

U

S

A

A

C

N

O

N

C

C

-

B

E

E

P

+

TRG

A

C

Altronix is not responsible for any typographical errors.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIDL1 - Rev. 110601

F15F

MEMBER

Advertising