Altronix DL3 Installation Instructions User Manual

Dl3 - door control timer, Specifications, Installation instructions

Advertising
background image

DL3 - Door Control Timer

Specifications:

• 12 - 24 volt AC or DC operation.
• DC “NC” and “NO” outputs to use with door magnet or door strike.
• Isolated AC or DC voltage 5V-24V trigger.
• Time adjustable from 1 second to 1 minute.
• On-board sounding device.
• Momentary or maintained trigger.
Board dimensions: 4.5"L x 1.31"W x .75"H

Installation Instructions:

1. Unit operates from 12-24 volts AC or DC. Voltage source should be connected to the terminals marked [AC].

When using DC power, polarity does not have to be observed.

2. Use “-- ”, “NC” and “NO” to operate desired devices (magnetic lock, door strike, etc.). During normal operation

positive power is connected to “NC” and transfers to “NO” when timing cycle is initiated.

3. Adjust desirable time. By turning timing potentiometer clockwise you increase the duration of the output.
4. Connect trigger voltage source to both terminals marked [TRG].

Note: Surge suppressors can be used to eliminate RMI that is generated when the electrical coil is powered down.
We recommend to use a diode in parallel with every DC coil magnet (Banded end of diode connected to positive
terminal of coil or magnet).

A

C
A

C

N

C
N

O

--

T

R

T

R

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIDL3 - Rev. 111306

C05I

MEMBER

Advertising