C&H Technology PM600HSA120 User Manual

Page 3

Advertising
background image

PM600HSA120
Intellimod™ Module
Half Phase IGBT Inverter Output
600 Amperes/1200 Volts

684

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Absolute Maximum Ratings,

T

j

= 25

°

C unless otherwise specified

Characteristics

Symbol

PM600HSA120

Units

Power Device Junction Temperature

T

j

-20 to 150

°

C

Storage Temperature

T

stg

-40 to 125

°

C

Case Operating Temperature

T

C

-20 to 100

°

C

Mounting Torque, M6 Mounting Screws

26

in-lb

Mounting Torque, M8 Main Terminal Screws

95

in-lb

Module Weight (Typical)

1090

Grams

Supply Voltage Protected by OC and SC (V

D

= 13.5 - 16.5V, Inverter Part)

V

CC(prot.)

800

Volts

Isolation Voltage, AC 1 minute, 60Hz Sinusoidal

V

RMS

2500

Volts

Control Sector

Supply Voltage Applied between (V

1

-V

C

)

V

D

20

Volts

Input Voltage Applied between (C

1

-V

C

)

V

CIN

10

Volts

Fault Output Supply Voltage (Applied between F

o

-V

c

)

V

FO

20

Volts

Fault Output Current

I

FO

20

mA

IGBT Inverter Sector

Collector-Emitter Voltage (V

D

= 15V, V

CIN

= 5V)

V

CES

1200

Volts

Collector Current,

±

I

C

600

Amperes

Peak Collector Current,

±

I

CP

1200

Amperes

Collector Dissipation

P

C

3470

Watts

Electrical and Mechanical Characteristics,

T

j

= 25

°

C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Over Current Trip Level Inverter Part

OC

-20

°

C

T

j

125

°

C

740

1000

Amperes

Short Circuit Trip Level Inverter Part

SC

-20

°

C

T

j

125

°

C

1000

1400

Amperes

Over Current Delay Time

t

off(OC)

V

D

= 15V

5

µ

S

Over Temperature Protection

OT

Trip Level

100

110

120

°

C

OT

R

Reset Level

85

95

105

°

C

Supply Circuit Under Voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

UV

R

Reset Level

12.5

Volts

Supply Voltage

V

D

Applied between V

1

-V

C

13.5

15

16.5

Volts

Circuit Current

I

D

V

D

= 15V, V

CIN

= 5V, V

1

-V

C

23

30

mA

Input ON Threshold Voltage

V

CIN(on)

Applied between C

1

-V

C

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

CIN(off)

Applied between C

1

-V

C

1.7

2.0

2.3

Volts

PWM Input Frequency

f

PWM

3-

л

Sinusoidal

15

20

kHz

Fault Output Current

I

FO(H)

V

D

= 15V, V

FO

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

FO

= 15V

10

15

mA

Minimum Fault Output Pulse Width

t

FO

V

D

= 15V

1.0

1.8

mS

SXR Terminal Output Voltage

V

SXR

T

j

125

°

C, Rin = 6.8 k

4.5

5.1

5.6

Volts

Advertising