TDK4_ _3302

Phase Control Thyristor

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724)925-7272

3300 Amperes 4500 Volts

Electrical Characteristics,

Tj=25°C unless otherwise specified

Rating

Characteristic

Symbol

Test Conditions

min

typ

max

Units

Repetitive Peak Forward

Leakage Current

I

DRM

Tj=125°C, V

DRM

=Rated

300

ma

Repetitive Peak Reverse

Leakage Current

I

RRM

Tj=125°C, V

RRM

=Rated

300

ma

Peak On-State Voltage

V

TM

Tj=125°C, I

TM

=3000A

1.60

V

V

TM

Model, Low Level

V

0

Tj=125°C

0.991269 V

VTM = V

O

+

r•

I

TM

r

15%

I

TM

- π•I

TM

1.96E-04

V

TM

Model, High Level

V

0

Tj=125°C

0.772002 V

VTM = V

O

+

r•

I

TM

r

π•I

TM

- I

TSM

2.18E-04

V

TM

Model, 4-Term

A

Tj=125°C

0.132

V

TM

= A + B•Ln(I

TM

) +

B

15%I

TM

- I

TSM

0.181

C•(I

TM

) + D•(I

TM

)

½

C

2.57E-04

D

-1.41E-02

Turn-On Delay Time

t

d

V

D

= 0.5•V

DRM

3

us

Gate Drive: 40V - 20Ω

Turn-Off Time (typ)

tq

Tj=125°C

400

us

dv/dt = 20V/us to 80% V

DRM

dv/dt

(Crit)

dv/dt

Tj=125°C Exp. Waveform

2000

V/us

V

D

=67% Rated

Gate Trigger Current

I

GT

Tj=25°C V

D

= 12V

40

100

300

ma

Gate Trigger Voltage

V

GT

0.8

2.0

4.0

V

Peak Reverse Gate Voltage

V

GRM

5

V

Thermal Characteristics

Rating

Characteristic

Symbol

Test Conditions

min

typ

max

Units

Thermal Resistance

Junction to Case

jc

Double side cooled

0.0055

0.007

°C/Watt

Case to Sink

cs

Double side cooled

0.0015

0.002

°C/Watt

Thermal Impedance Model

jc

Double side cooled

jc

(t) =

Σ(A(

N

)•(1-exp(-t/

Tau

(

N

))))

where:

N =

1

2

3

4

A(N

) =

1.43E-04

9.38E-04

2.42E-03

3.50E-03

T

au(N) =

2.62E-03

2.31E-02

3.05E-01

3.30E+00

Page 3