C&H Technology PM450CLA060 User Manual

Page 4

Advertising
background image

3

PM450CLA060
Intellimod™ L-Series
Three Phase IGBT Inverter
450 Amperes/600 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

IGBT Inverter Sector

Collector-Emitter Cutoff Current

I

CES

V

CE

= V

CES

, V

CIN

= 15V, T

j

= 25°C

1.0

mA

V

CE

= V

CES

, V

CIN

= 15V, T

j

= 125°C

10

mA

Diode Forward Voltage

V

EC

-I

C

= 450A, V

CIN

= 15V, V

D

= 15V

2.6

3.7

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

V

D

= 15V, V

CIN

= 0V, I

C

= 450A,

1.7

2.2

Volts

T

j

= 25°C

V

D

= 15V, V

CIN

= 0V, I

C

= 450A,

1.8

2.3

Volts

T

j

= 125°C

Inductive Load Switching Times

t

on

0.5

1.0

2.4

µs

t

rr

V

D

= 15V, V

CIN

= 0 1 15V

0.2

0.4

µs

t

C(on)

V

CC

= 300V, I

C

= 450A

0.4

1.0

µs

t

off

T

j

= 125°C

2.2

3.5

µs

t

C(off)

0.6

1.1

µs

Control Sector

Short Circuit Trip Level

SC

-20°C ≤ T

j

≤ 125°C, V

D

= 15V

900

Amperes

Short Circuit Current Delay Time

t

off(SC)

V

D

= 15V

0.2

µs

Over Temperature Protection

OT

Trip Level

135

145

°C

(Detect T

j

of IGBT Chip)

OT

R

Reset Level

125

°C

Supply Circuit Under-voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

(-20 ≤ T

j

≤ 125°C)

UV

R

Reset Level

12.5

Volts

Circuit Current

I

D

Upper Arm V

D

= 15V, V

CIN

= 15V

11

18

mA

Lower Arm V

D

= 15V, V

CIN

= 15V

11

18

mA

Input ON Threshold Voltage

V

th(on)

Applied between U

P

-V

UPC

, V

P

-V

VPC

,

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

th(off)

W

P

-V

WPC

, U

N

-V

UNC

, V

N

-V

VNC

, W

N

-V

WNC

1.7

2.0

2.3

Volts

Fault Output Current*

I

FO(H)

V

D

= 15V, V

FO

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

FO

= 15V

10

15

mA

Fault Output Pulse Width*

t

FO

V

D

= 15V

1.0

1.8

ms

*Fault output is given only when the internal SC, OT and UV protection of either upper or lower arms is tripped.

Advertising