C&H Technology QR_0640T30 User Manual

Page 3

Advertising
background image



Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Fast Recovery Diode Module

www.pwrx.com

Revision Date: 03/23/2009

QR_0640T30

Absolute Maximum Ratings, T

J

=25

°C unless otherwise specified

Characteristics Conditions

Symbol

QRD0640T30

QRC0640T30

QRF0640T30 Units

Repetitive Peak Reverse Blocking Voltage

-

V

RRM

600 Volts

Non-Repetitive Peak Reverse Blocking Voltage

-

V

RSM

V

RRM

+ 100

Volts

Average Forward Current

180

° Conduction, Tc=80°C

180

° Conduction, Tc=25°C

I

F(AV)

136

208

Amperes

Amperes

Peak Half Cycle Non-Repetitive Surge Current

t = 8.3mS, 100%V

RRM

Reapplied

I

FSM

2400 Amperes

I

2

t for Fusing for One Cycle

t = 8.3mS, 100%V

RRM

Reapplied

I

2

t 24000 A

2

sec

Operating Junction Temperature

-

T

J

-40 to 150

°C

Storage Temperature

-

T

STG

-40 to 150

°C

Maximum Mounting Torque, M6 Mounting Screw

-

-

26

In.-lb.

Maximum Terminal Torque, M6 Terminal Screw

-

-

26

In.-lb.

Module Weight (Typical)

-

-

220

Grams

V Isolation

60 Hz, circuit to base, all terminals
shorted, t = 1 sec

V

RMS

3000 Volts



Thermal Characteristics, T

J

=25

°C unless otherwise specified

Characteristics Symbol

Min.

Typ.

Max.

Units

Thermal Resistance, Junction to Case

R

ΘJC

Per Diode

-

-

0.18

°C/Watt

Thermal Resistance, Case to Sink Lubricated

R

ΘCS

Per Module

-

-

0.04

°C/Watt


Electrical Characteristics, T

J

=25

°C unless otherwise specified

Characteristics Symbol

Test

Conditions

Min.

Typ.

Max

Units

Peak Reverse Leakage Current

I

RRM

Rated

V

RRM

-

-

1

mA

Peak On-State Voltage

V

FM

I

F

=400A -

-

2.8

Volts

Reverse Recovery Time

trr

I

F

= 400A, di/dt =

−800A/μs

- -

110

ns

Reverse Recovery Charge

Qrr

I

F

= 400A, di/dt =

−800A/μs

- 1.08 -

μC