C&H Technology CM75RX-24S User Manual

Page 8

Advertising
background image

CM75RX-24S
Six IGBTMOD™ + Brake NX-S Series Module
75 Amperes/1200 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

6

06/11 Rev. 3

COLLECTOR-EMITTER VOLTAGE, V

CE

, (VOLTS)

CAPACITANCE, C

ies

, C

oes

, C

res

, (nF)

CAPACITANCE VS. VCE

(INVERTER PART - TYPICAL)

10

0

10

2

10

2

10

1

10

0

10

-1

10

-2

10

1

0.5

1.0

2.0

1.5

2.5

10

1

EMITTER-COLLECTOR VOLTAGE, V

EC

, (VOLTS)

FREE-WHEEL DIODE

FORWARD CHARACTERISTICS

(INVERTER PART - TYPICAL)

10

2

10

3

EMITTER CURRENT, I

E

, (AMPERES)

COLLECTOR CURRENT, I

C

, (AMPERES)

COLLECTOR-EMITTER

SATURATION VOLTAGE, V

CE

, (VOLTS)

COLLECTOR-EMITTER

SATURATION VOLTAGE CHARACTERISTICS

(INVERTER PART - TYPICAL)

10

6

8

10

14

12

16

18

20

8

6

4

2

0

T

j

= 25°C

V

GE

= 0V

C

ies

C

oes

C

res

I

C

= 150A

I

C

= 75A

I

C

= 30A

COLLECTOR-EMITTER VOLTAGE, V

CE

, (VOLTS)

COLLECTOR CURRENT, I

C

, (AMPERES)

OUTPUT CHARACTERISTICS

(INVERTER PART - TYPICAL)

0

2

4

6

8

10

0

V

GE

= 20V

10

11

12

13

9

T

j

= 25°

C

150

25

50

75

100

125

COLLECTOR CURRENT, I

C

, (AMPERES)

COLLECTOR-EMITTER

SATURATION VOLTAGE, V

CE

, (VOLTS

)

COLLECTOR-EMITTER

SATURATION VOLTAGE CHARACTERISTICS

(INVERTER PART - TYPICAL)

3.5

3.0

0

2.0

2.5

1.0

1.5

0.5

0

150

75

100

125

25

50

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

10

3

10

0

10

1

10

2

10

0

10

1

SWITCHING TIME, (ns)

HALF-BRIDGE

SWITCHING CHARACTERISTICS

(INVERTER PART - TYPICAL)

t

d(off)

t

d(on)

t

r

V

CC

= 600V

V

GE

= ±15V

R

G

= 8.2Ω

T

j

= 150°C

Inductive Load

t

f

10

2

COLLECTOR CURRENT, I

C

, (AMPERES)

10

3

10

0

10

1

10

2

10

0

10

1

SWITCHING TIME, (ns)

HALF-BRIDGE

SWITCHING CHARACTERISTICS

(INVERTER PART - TYPICAL)

t

d(off)

t

d(on)

t

r

V

CC

= 600V

V

GE

= ±15V

R

G

= 8.2Ω

T

j

= 125°C

Inductive Load

t

f

10

2

EXTERNAL GATE RESISTANCE, R

G

, (Ω)

10

3

10

0

10

1

10

2

10

1

SWITCHING TIME, (ns)

SWITCHING TIME VS.

GATE RESISTANCE

(INVERTER PART - TYPICAL)

t

d(off)

t

d(on)

t

r

V

CC

= 600V

V

GE

= ±15V

I

C

= 75A

T

j

= 150°C

Inductive Load

t

f

10

2

EXTERNAL GATE RESISTANCE, R

G

, (Ω)

10

3

10

0

10

1

10

2

10

1

SWITCHING TIME, (ns)

SWITCHING TIME VS.

GATE RESISTANCE

(INVERTER PART - TYPICAL)

t

d(off)

t

d(on)

t

r

V

CC

= 600V

V

GE

= ±15V

I

C

= 75A

T

j

= 125°C

Inductive Load

t

f

10

2

15

T

j

= 25°C

T

j

= 125°C

T

j

= 150°C

T

j

= 25°C

T

j

= 125°C

T

j

= 150°C

Advertising