Hvm-2017 – C&H Technology RM900HC-90S User Manual

Page 3

Advertising
background image

MITSUBISHI ELECTRIC CORPORATION

HIGH VOLTAGE DIODE MODULE

HVM-2017

(HV-SETSU)

PAGE

2 / 11

6. Maximum Ratings

Item Symbol

Conditions

Ratings

Unit

6.1 Repetitive peak reverse voltage V

RRM

T

j

= 25 °C

4500

V

6.2 Non-repetitive peak reverse

voltage

V

RSM

T

j

= 25 °C

4500

V

6.3 Reverse DC voltage

V

R(DC)

T

j

= 25 °C

3200

V

6.4 DC forward current

I

F

T

c

= 25 °C

900

A

6.5 Surge forward current

I

FSM

T

j

= 25 °C start, t

w

= 8.3 ms

Half sign wave

7200 A

6.6 Surge current load integral

I

2

t

T

j

= 25 °C start, t

w

= 8.3 ms

Half sign wave

216 kA

2

s

6.7 Isolation voltage

V

iso

Charged part to the baseplate
RMS sinusoidal, 60Hz 1min.

6000 V

6.8 Junction temperature

T

j

−40 ~ +150

°C

6.9 Storage temperature

T

stg

−40 ~ +125

°C

6.10 Operating temperature

T

op

−40 ~ +125

°C

6.11 Maximum reverse recovery

instantaneous power

V

R

≤ 3200 V

di/dt ≤ 3300A/µs, T

j

= 125 °C

[See Fig.1, Fig.2, 12-5]

1800 kW


7. Electrical

Characteristics

Limits

Item Symbol

Conditions

Min. Typ. Max.

Unit

T

j

= 25 °C

— — 5

7.1 Repetitive reverse current

I

RRM

V

RM

= V

RRM

T

j

= 125 °C

— 10 30

mA

T

j

= 25 °C

— 4.80 5.8

7.2 Forward voltage

V

FM

(Note 1)

I

F

= 900 A

T

j

= 125 °C

— 4.15 —

V

7.3 Reverse recovery time

t

rr

1.0

µs

7.4 Reverse recovery current

I

rr

840

A

7.5 Reverse recovery charge

Q

rr

750

µC

7.6 Reverse recovery energy

E

rec

V

R

= 2250 V, I

F

= 900 A

di/dt = −1850 A/µs
T

j

= 125 °C

[See Fig.1,Fig.2]

— 1.00 — J/P

Note 1: It doesn't include the voltage drop by Internal lead resistance.

Advertising