C&H Technology PM400DVA060 User Manual

Page 4

Advertising
background image

409

PM400DVA060
Intellimod™ Module
Single Phase IGBT Inverter Output
400 Amperes/600 Volts

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics,

T

j

= 25

°

C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Short Circuit Trip Level

SC

-20

°

C

T

j

125

°

C, V

D

= 15V

650

910

Amperes

Short Circuit Current Delay Time

t

off(SC)

V

D

= 15V

10

µ

S

Over Temperature Protection

OT

Trip Level

100

110

120

°

C

(V

D

= 15V, Lower Arm)

OT

r

Reset Level

85

95

105

°

C

Supply Circuit Under Voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

(-20

°

C

T

j

125

°

C)

UV

r

Reset Level

12.5

Volts

Circuit Current

I

D

V

D

= 15V, V

CIN

= 5V, V

N1

-V

NC

23

30

mA

V

D

= 15V, V

CIN

= 5V, V

P1

-V

PC

23

30

mA

Input ON Threshold Voltage

V

CIN(on)

Applied between

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

CIN(off)

C

P1

-V

PC

, C

N1

-V

NC

1.7

2.0

2.3

Volts

Fault Output Current

I

FO(H)

V

D

= 15V, V

FO

= 15V*

0.01

mA

I

FO(L)

V

D

= 15V, V

FO

= 15V*

10

15

mA

Minimum Fault Output Pulse Width

t

FO

V

D

= 15V*

1.0

1.8

mS

SXR Terminal Output Voltage

V

SXR

T

j

125

°

C, R

in

= 6.8k

(S

PR

, S

NR

)

4.5

5.1

5.6

Volts

* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.

Advertising