C&H Technology PM75B6L1C060 User Manual

Page 3

Advertising
background image

PM75B6L1C060
Photo Voltaic IPM
H-Bridge + 2 Choppers
75 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com

2

03/11 Rev. 0

Absolute Maximum Ratings,

T

j

= 25°C unless otherwise specified

Characteristics

Symbol PM75B6L1C060 Units

Power Device Junction Temperature

T

j

-20 to 150

°C

Storage Temperature

T

stg

-40 to 125

°C

Mounting Torque, M4 Mounting Screws (Typical)

15

in-lb

Module Weight (Typical)

135

Grams

Supply Voltage, Surge (Applied between P-N)

V

CC(surge)

500 Volts

Operation of Short Circuit Protections

V

CC(prot.)

450 Volts

(Applied between P-N, V

D

= 13.5 ~ 16.5V, Inverter Part, T

j

= 125°C Start)

Isolation Voltage (60Hz, Sinusoidal, RMS, Charged Part to Base, AC 1 Minute)

V

ISO

2500 Volts

Inverter Part

Collector-Emitter Voltage (V

D

= 15V, V

CIN

= 15V)

V

CES

600 Volts

Collector Current (T

C

= 25°C)

I

C

75 Amperes

Collector Current (Pulse)

I

CRM

150 Amperes

Total Power Dissipation (T

C

= 25°C)

P

tot

201 Watts

Emitter Current (T

C

= 25°C, FWDi Current)

I

E

75 Amperes

Emitter Current (Pulse, FWDi Current)

I

ERM

150 Amperes

Converter Part

Collector-Emitter Voltage (V

D

= 15V, V

CIN

= 15V)

V

CES

600 Volts

Collector Current (T

C

= 25°C)

I

C

75 Amperes

Collector Current (Pulse)

I

CRM

150 Amperes

Total Power Dissipation (T

C

= 25°C)

P

tot

201 Watts

Emitter Current (T

C

= 25°C, FWDi Current)

I

E

75 Amperes

Emitter Current (Pulse, FWDi Current)

I

ERM

150 Amperes

Diode Forward Current (T

C

= 25°C)

I

F

75 Amperes

Diode Rated DC Reverse Voltage (T

C

= 25°C)

V

R(DC)

600 Volts

Control Part

Supply Voltage (Applied between V

UP1

-V

UPC

, V

VP1

-V

VPC

, V

N1

-V

NC

) V

D

20 Volts

Input Voltage (Applied between U

P

-V

UPC

, V

P

-V

VPC

, U

N

- V

N

- W

N

-Br-V

NC

) V

CIN

20 Volts

Fault Output Supply Voltage

V

FO

20 Volts

(Applied between U

FO

-V

UPC

, V

FO

-V

VPC

, F

O

-V

NC

)

Fault Output Supply Current (Sink Current at U

FO

, V

FO

, F

O

Terminals) I

FO

20 mA

Advertising