C&H Technology PM100RSD060 User Manual

Page 7

Advertising
background image

PM100RSD060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
100 Amperes/600 Volts

6

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

0

0.5

1.0

2.0

1.5

SATURATION VOLTAGE

CHARACTERISTICS (TYPICAL)

(INVERTER PART)

COLLECTOR CURRENT, I

C

, (AMPERES)

SATURATION VOLTAGE, V

CE(sat)

, (VOLTS)

0

20

100

40

60

80

V

D

= 15V

T

j

= 25

o

C

T

j

= 125

o

C

V

CIN

= 0V

10

1

10

2

10

3

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES, t

on

, t

off

, (

µ

s)

SWITCHING TIME VS.

COLLECTOR CURRENT (TYPICAL)

10

0

10

1

t

off

t

on

10

1

10

2

10

3

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES, t

c(on)

, t

c(off)

, (

µ

s)

SWITCHING TIME VS.

COLLECTOR CURRENT (TYPICAL)

t

c(off)

t

c(off)

t

c(on)

10

0

10

1

10

1

10

2

10

3

10

-2

COLLECTOR CURRENT, I

C

, (AMPERES)

REVERSE RECOVERY TIME, t

rr

, (

µ

S)

REVERSE RECOVERY CURRENT VS.

COLLECTOR CURRENT (TYPICAL)

10

-1

10

0

t

rr

V

CC

= 300V

V

D

= 15V

T

j

= 25

o

C

T

j

= 125

o

C

10

0

REVERSE RECOVERY CURRENT, I

rr

, (AMPERES)

10

1

10

2

I

rr

0

1.0

2.5

10

0

DIODE FORWARD VOLTAGE, V

EC

, (VOLTS)

DIODE CURRENT, -I

C

, (AMPERES)

DIODE FORWARD CHARACTERISTICS

(INVERTER PART)

10

1

10

2

0.5

1.5

2.0

T

j

= 25

o

C

T

j

= 125

o

C

V

D

= 15V

V

CC

= 300V

V

D

= 15V

T

j

= 25

o

C

T

j

= 125

o

C

INDUCTIVE LOAD

V

CC

= 300V

V

D

= 15V

T

j

= 25

o

C

T

j

= 125

o

C

INDUCTIVE LOAD

10

1

10

2

10

3

10

-1

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING LOSS, E

SW

(mJ/PULSE)

10

0

10

1

E

sw(on)

E

sw(off)

CONDITIONS:
HALF-BRIDGE INDUCTIVE LOAD
SWITCHING OPERATION

V

CC

= 300V

V

GE

=

±

15V

T

j

= 25

o

C

T

j

= 125

o

C

INDUCTIVE LOAD

TIME, (s)

TRANSIENT IMPEDANCE, Z

th(

j-

c

)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS
(IGBT & FWDi - INVERTER PART)

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

10

-2

10

-3

TIME, (s)

TRANSIENT IMPEDANCE, Z

th(

j-

c

)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(IGBT & FWDi - BRAKE PART)

SWITCHING LOSS CHARACTERISTICS

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

10

-2

10

-3

STANDARD VALUE
R

th(j-c)Q

= 0.38

o

C/W (IGBT)

R

th(j-c)Q

= 0.70

o

C/W (FWDi)

SINGLE PULSE

STANDARD VALUE
R

th(j-c)Q

= 0.71

o

C/W (IGBT)

R

th(j-c)Q

= 1.66

o

C/W (FWDi)

SINGLE PULSE

Advertising