Absolute maximum ratings, t, 25°c unless otherwise specified, Igbt inverter sector – C&H Technology PS22052 User Manual

Page 3: Control sector

Advertising
background image

PS22052
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/1200 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

2

Rev. 10/05

Absolute Maximum Ratings, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

PS22052

Units

Power Device Junction Temperature*

T

j

-20 to 125

°C

Module Case Operation Temperature (See Note 1)

T

C

-20 to 100

°C

Storage Temperature

T

stg

-40 to 125

°C

Mounting Torque, M4 Mounting Screws

13

in-lb

Module Weight (Typical)

77

Grams

Self-protection Supply Voltage Limit (Short Circuit Protection Capability)**

V

CC(prot.)

800

Volts

Heatsink Flatness (See Note 2)

-50 to 100

µm

Isolation Voltage, AC 1 minute, 60Hz Sinusoidal, Connection Pins to Heatsink Plate

V

ISO

2500

Volts

*The maximum junction temperature rating of the power chips integrated within the DIP-IPM is 150°C (@T

C

≤ 100°C). However, to ensure safe operation of the DIP-IPM,

the average junction temperature should be limited to T

j(avg)

≤ 125°C (@T

C

≤ 100°C).

**V

D

= 13.5 ~ 16.5V, Inverter Part, T

j

= 125°C, Non-repetitive, Less than 2µs

IGBT Inverter Sector

Collector-Emitter Voltage

V

CES

1200

Volts

Collector Current (T

C

= 25°C)

±I

C

5

Amperes

Peak Collector Current (T

C

= 25°C, <1ms)

±I

CP

10

Amperes

Supply Voltage (Applied between P-NU, NV, NW)

V

CC

900

Volts

Supply Voltage, Surge (Applied between P-NU, NV, NW)

V

CC(surge)

1000

Volts

Collector Dissipation (T

C

= 25°C, per 1 Chip)

P

C

38.3

Watts

Control Sector

Supply Voltage (Applied between V

P1

-V

PC

, V

N1

-V

NC

)

V

D

20

Volts

Supply Voltage (Applied between V

UFB

-V

UFS

,

V

VFB

-V

VFS

, V

WFB

-V

WFS

)

V

DB

20

Volts

Input Voltage (Applied between U

P

, V

P

, W

P

-V

PC

, U

N

, V

N

, W

N

-V

NC

)

V

IN

-0.5 ~ V

D

+0.5

Volts

Fault Output Supply Voltage (Applied between F

O

-V

NC

)

V

FO

-0.5 ~ V

D

+0.5

Volts

Fault Output Current (Sink Current at F

O

Terminal)

I

FO

1

mA

Current Sensing Input Voltage (Applied between C

IN

-V

NC

)

V

SC

-0.5 ~ V

D

+0.5

Volts

TC POINT

POWER TERMINALS

CONTROL TERMINALS

HEATSINK

BOUNDARY

Note 1 – T

C

Measure Point

Note 2 – Flatness Measurement Position

HEATSINK

MEASUREMENT POINT

3.25mm

HEATSINK

+

+

Advertising