background image

PS21964-4, PS21964-4A, PS21964-4C
Intellimod™ Module
Dual-In-Line Intelligent Power Module
15 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

4

Rev. 12/09

Thermal Characteristics

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Junction to Case

R

th(j-c)Q

Inverter IGBT (Per 1/6 Module)

3.0

°C/Watt

R

th(j-c)D

Inverter FWDi (Per 1/6 Module)

3.9

°C/Watt

Recommended Conditions for Use

Characteristic

Symbol

Condition

Min.

Typ.

Value

Units

Supply Voltage

V

CC

Applied between P-N Terminals

0

300

400

Volts

Control Supply Voltage

V

D

Applied between V

P1

-V

NC

, V

N1

-V

NC

13.5

15.0

16.5

Volts

V

DB

Applied between V

UFB

-U,

13.0

15.0

18.5

Volts

V

VFB

-V, V

WFB

-W

Control Supply Variation

dV

D

, dV

DB

-1

1

V/µs

Arm Shoot-through Blocking Time

t

DEAD

For Each Input Signal, T

C

≤ 100°C

1.5

µs

Allowable Minimum Input

P

WIN(on)

0.5

µs

Pulse Width*

P

WIN(off)

0.5

µs

V

NC

Voltage Variation

V

NC

Between V

NC

-N (Including Surge)

-5.0

5.0

Volts

*DIP-IPM might not make response or work properly if the input signal plus width is less than the recommended minimum value.