PS21997-4, PS21997-4A
Intellimod™ Module
Dual In-line Intelligent Power Module
30 Amperes/600 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

5

10/09

+

C2

C1

C6

C5

+

AC LINE

DZ1

R1 D1

C2

C3

VUFB

UP

VWFB

VVFB

C4

VP1

VNC

UN

VN

WN

VN1

VP

WP

NC

VNC

CIN

FO

+15V

+3.3 to +5V

+VCC

LVIC

HVIC

+VCC

GATE DRIVE

UV PROT.

LEVEL

SHIFT

GATE DRIVE

UV PROT.

LEVEL

SHIFT

GATE DRIVE

UV PROT.

LEVEL

SHIFT

P

U

V

W

N

MOTOR

CONTR

OLLER

Component Selection:
Dsgn.

Typ. Value

Description

Notes:

G

ATE DRIVE

RSHUNT

This symbol indicates
connection to ground plane.

+

C2

C1 DZ1

R1 D1

+

+

C2

C1 DZ1

R1

R2

C4

R2

C4

R2

C2

DZ1

CSF

C4

C4

R2

C4

R2

R2

C4

R3

R2

RSF

D1

FAULT LOGIC

INPUT SIGNAL

CONDITIONING

UV

PROT.

OVER CURRENT

PROTECTION

D1

1A, 600V

Boot strap supply diode – Ultra fast recovery

DZ1

24V, 1.0W

Control and boot strap supply over voltage suppression

C1

10-100uF, 50V

Boot strap supply reservoir – Electrolytic, long life, low Impedance, 105°C (Note 5)

C2

0.22-2.0uF, 50V

Local decoupling/High frequency noise filters – Multilayer ceramic (Note 8)

C3

10-100uF, 50V

Control power supply filter – Electrolytic, long life, low Impedance, 105°C

C4

100pF, 50V

Optional Input signal noise filter – Multilayer ceramic (Note 1)

C5

200-2000uF, 450V

Main DC bus filter capacitor – Electrolytic, long life, high ripple current, 105°C

C6

0.1-0.22uF, 450V

Surge voltage suppression capacitor – Polyester/Polypropylene film (Note 9)

CSF

1000pF, 50V

Short circuit detection filter capacitor – Multilayer Ceramic (Note 6, Note 7)

RSF

1.8k ohm

Short circuit detection filter resistor (Note 6, Note 7)

RSHUNT

5-100mohm

Current sensing resistor – Non-inductive, temperature stable, tight tolerance (Note 10)

R1

10 ohm

Boot strap supply inrush limiting resistor (Note 5)

R2

330 ohm

Optional control input noise filter (Note 1, Note 2)

R3

10k ohm

Fault output signal pull-up resistor (Note 3)

1) To prevent input signal oscillations minimize wiring length to controller (~2cm). Additional RC filtering (C5 etc.) may be required.

If filtering is added be careful to maintain proper dead time and voltage levels. See application notes for details.

2) Internal HVIC provides high voltage level shifting allowing direct connection of all six driving signals to the controller.
3) FO output is an open collector type. Pull up resistor (R3) should be adjusted to current sink capability of the controller.

4) Use only one VNC Pin (either 9 or 16) and leave the other open.

5) Boot strap supply component values must be adjusted depending on the PWM frequency and technique.
6) Wiring length associated with RSHUNT, RSF, CSF must be minimized to avoid improper operation of the OC function.

7) RSF, CSF set over current protection trip time. Recommend time constant is 1.5µs-2.0µs. See application notes.

8) Local decoupling/high frequency filter capacitors must be connected as close as possible to the modules pins.
9) The length of the DC link wiring between C5, C6, the DIP’s P terminal and the shunt must be minimized to prevent excessive

transient voltages. In particular C6 should be mounted as close to the DIP as possible.

10) Use high quality, tight tolerance current sensing resistor. Connect resistor as close as possible to the DIP’s N terminal. Be careful

to check for proper power rating. See application notes for calculation of resistance value.