C&H Technology PM50RSA120 User Manual

Page 4

Advertising
background image

609

PM50RSA120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
50 Amperes/1200 Volts

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics,

T

j

= 25

°

C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Over Current Trip Level Inverter Part

OC

-20

°

C

T

125

°

C

59

112

Amperes

Over Current Trip Level Brake Part

22

50

Amperes

Short Circuit Trip Level Inverter Part

SC

-20

°

C

T

125

°

C

183

Amperes

Short Circuit Trip Level Brake Part

95

Amperes

Over Current Delay Time

t

off(OC)

V

D

= 15V

10

µ

S

Over Temperature Protection

OT

Trip Level

111

118

125

°

C

OT

R

Reset Level

100

°

C

Supply Circuit Under Voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

UV

R

Reset Level

12.5

Volts

Supply Voltage

V

D

Applied between V

UP1

-V

UPC

,

13.5

15

16.5

Volts

V

VP1

-V

VPC

, V

WP1

-V

WPC

, V

N1

-V

NC

Circuit Current

I

D

V

D

= 15V, V

CIN

= 15V, V

N1

-V

NC

44

60

mA

V

D

= 15V, V

CIN

= 15V, V

XP1

-V

XPC

13

18

mA

Input ON Threshold Voltage

V

CIN(on)

Applied between

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

CIN(off)

U

P

, V

P

, W

P

, U

N

, V

N

, W

N

, B

r

1.7

2.0

2.3

Volts

PWM Input Frequency

f

PWM

3-

л

Sinusoidal

15

20

kHz

Fault Output Current

I

FO(H)

V

D

= 15V, V

FO

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

FO

= 15V

10

15

mA

Minimum Fault Output Pulse Width

t

FO

V

D

= 15V

1.0

1.8

mS

Advertising