C&H Technology PM200DSA120 User Manual

Page 7

Advertising
background image

PM200DSA120
Intellimod™ Module
Single Phase IGBT Inverter Output
200 Amperes/1200 Volts

664

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

60

80

100

120

140

FAULT OUTPUT PULSE WIDTH VS.

TEMPERATURE (TYPICAL)

JUNCTION TEMPERATURE, T

C

, (

o

C)

FAULT OUTPUT PULSE WIDTH % (NORMALIZED)

0

40

80

120

160

V

D

= 15V

0

10

11

12

13

14

CONTROL SUPPLY VOLTAGE TRIP-RESET

LEVEL TEMPERATURE DEPENDENCY

(TYPICAL)

JUNCTION TEMPERATURE, T

C

, (

o

C)

UV TRIP-RESET LEVEL,

UV, UV

r

, (VOLTS)

0

160

40

80

120

UV
UV

r

0

TIME, (s)

TRANSIENT IMPEDANCE, Z

th

(j-c)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(IGBT)

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

SINGLE PULSE
STANDARD VALUE = R

th(j-c)Q

= 0.11

o

C/W

10

-2

10

-3

TIME, (s)

TRANSIENT IMPEDANCE, Z

th

(j-c)

, (NORMALIZED VALUE)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(FWDi)

10

1

10

-1

10

0

10

1

10

0

10

-1

10

-2

10

-3

SINGLE PULSE
STANDARD VALUE = R

th(j-c)D

= 0.18

o

C/W

10

-2

10

-3

Advertising