Absolute maximum ratings, t, 25 ° c unless otherwise specified, Igbt inverter sector – C&H Technology PM100RSD120 User Manual

Page 3: Igbt brake sector, Control sector

Advertising
background image

PM100RSD120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
100 Amperes/1200 Volts

2

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Absolute Maximum Ratings,

T

j

= 25°C unless otherwise specified

Characteristics

Symbol

PM100RSD120

Units

Power Device Junction Temperature

T

j

-20 to 150

°

C

Storage Temperature

T

stg

-40 to 125

°

C

Case Operating Temperature

*

T

C

-20 to 100

°

C

Mounting Torque, M5 Mounting Screws

31

in-lb

Mounting Torque, M5 Main Terminal Screws

31

in-lb

Module Weight (Typical)

920

Grams

Supply Voltage Protected by OC and SC

V

CC(prot.)

800

Volts

(V

D

= 13.5 - 16.5V, Inverter Part) T

j

= 125

°

C Start

Isolation Voltage, AC 1 minute, 60Hz Sinusoidal

V

ISO

2500

Volts

IGBT Inverter Sector

Collector-Emitter Voltage (V

D

= 15V, V

CIN

= 15V)

V

CES

1200

Volts

Collector Current,

±

(T

C

= 25

°

C)

I

C

100

Amperes

Peak Collector Current,

±

(T

C

= 25

°

C)

I

CP

200

Amperes

Supply Voltage (Applied between P - N)

V

CC

800

Volts

Supply Voltage, Surge (Applied between P - N)

V

CC(surge)

1000

Volts

Collector Dissipation (T

C

= 25

°

C)

P

C

595

Watts

IGBT Brake Sector

Collector-Emitter Voltage (V

D

= 15V, V

CIN

= 15V)

V

CES

1200

Volts

Collector Current,

±

(T

C

= 25

°

C)

I

C

50

Amperes

Peak Collector Current,

±

(T

C

= 25

°

C)

I

CP

100

Amperes

FWDi Rated DC Reverse Voltage (T

C

= 25

°

C)

V

R(DC)

1200

Volts

FWDi Forward Current (T

C

= 25

°

C)

I

F

50

Amperes

Collector Dissipation (T

C

= 25

°

C)

P

C

416

Watts

Control Sector

Supply Voltage Applied between (V

UP1

-V

UPC

, V

VP1

-V

VPC

, V

WP1

-V

WPC

, V

N1

-V

NC

)

V

D

20

Volts

Input Voltage Applied between (U

P

-V

UPC

, V

P

-V

VPC

, W

P

-V

WPC

, U

N

,

V

N

, W

N

, B

r

-V

NC

)

V

CIN

20

Volts

Fault Output Supply Voltage Applied between

V

FO

20

Volts

(U

FO

-V

UPC

, V

FO

-V

VPC

, W

FO

-V

WPC

, F

O

-V

NC

)

Fault Output Current (U

FO

, V

FO

, W

FO

, F

O

)

I

FO

20

mA

*

T

C

Measure Point

63MM

T

C

10

12

N

V

B

P

W

U

3 4

5 6 7 8

9 11

12

14 16 18

13 15 17 19

Advertising