C&H Technology PM100RLA120 User Manual

Page 4

Advertising
background image

3

PM100RLA120
Intellimod™ L-Series
Three Phase IGBT Inverter + Brake
100 Amperes/1200 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

IGBT Inverter Sector

Collector-Emitter Cutoff Current

I

CES

V

CE

= V

CES

, V

D

= 15V, T

j

= 25°C

1.0

mA

V

CE

= V

CES

, V

D

= 15V, T

j

= 125°C

10

mA

Diode Forward Voltage

V

EC

-I

C

= 100A, V

CIN

= 15V, V

D

= 15V

2.5

3.5

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

V

D

= 15V, V

CIN

= 0V, I

C

= 100A,

1.8

2.3

Volts

T

j

= 25°C

V

D

= 15V, V

CIN

= 0V, I

C

= 100A,

1.9

2.4

Volts

T

j

= 125°C

Inductive Load Switching Times

t

on

0.5

1.0

2.5

µs

t

rr

V

D

= 15V, V

CIN

= 0 ⇔ 15V

0.5

0.8

µs

t

C(on)

V

CC

= 600V, I

C

= 100A

0.4

1.0

µs

t

off

T

j

= 125°C

2.0

3.0

µs

t

C(off)

0.7

1.2

µs

IGBT Brake Sector

Collector-Emitter Cutoff Current

I

CES

V

CE

= V

CES

, V

D

= 15V, T

j

= 25°C

1.0

mA

V

CE

= V

CES

, V

D

= 15V, T

j

= 125°C

10

mA

Diode Forward Voltage

V

FM

I

F

= 50A

2.5

3.5

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

V

D

= 15V, V

CIN

= 0V, I

C

= 50A,

1.8

2.3

Volts

T

j

= 25°C

V

D

= 15V, V

CIN

= 0V, I

C

= 50A,

1.9

2.4

Volts

T

j

= 125°C

Note 1: T

C

Baseplate Measurement Point

TOP VIEW

TC

MEASUREMENT

POINT

Advertising