PS22A73

Intellimod™ Module

Dual-In-Line Intelligent Power Module

10 Amperes/1200 Volts

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272

4

Rev. 08/09

Thermal Characteristics, T

j

= 25°C unless otherwise specified

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Thermal Resistance Junction to Case R

th(j-C)Q

IGBT Part (Per 1/6 Module)

1.51

°C/Watt

Thermal Resistance Junction to Case R

th(j-C)D

FWDi Part (Per 1/6 Module)

1.78 °C/Watt

Recommended Conditions for Use

Characteristic

Symbol

Condition

Min.

Typ.

Max.

Units

Supply Voltage

V

CC

Applied between P-NU, NV, NW

350

600

800

Volts

Control Supply Voltage

V

D

Applied between V

P1

-V

PC

, V

N1

-V

NC

13.5

15.0

16.5

Volts

V

DB

Applied between V

UFB

-V

UFS

,

13.0

15.0

18.5

Volts

V

VFB

-V

VFS

, V

WFB

-V

WFS

Control Supply Variation

ΔV

D

, ΔV

DB

-1

1

V/µs

Arm Shoot-through

t

DEAD

For Each Input Signal, T

C

≤ 100°C

3.3

µs

Blocking Time
PWM Input Frequency

f

PWM

T

C

100°C, T

j

≤ 125°C

15

kHz

Allowable rms Current*

I

O

V

CC

= 600V, V

D

= 15V,

3.6

Arms

f

C

= 15kHz, PF = 0.8, Sinusoidal PWM,

T

j

≤ 125°C, T

C

≤ 100°C

Minimum Input

P

WIN(on)

**

µs

Pulse Width

P

WIN(off)***

I

C

≤ 10A

350 ≤ V

CC

≤ 800V, 13.5 ≤ V

D

≤ 16.5V,

µs

10 ≤ I

C

17A

13.5 ≤ V

DB

≤ 16.5V, -20°C ≤ T

C

≤ 100°C,

µs

N-line Wiring Inductance Less Than 10nH

V

NC

Variation

V

NC

Between V

NC

-NU, NV, NW (Including Surge)

-5.0

5.0

Volts

* The allowable rms current value depends on the actual application conditions.
**If input signal ON pulse is less than PWIN(on), the device may not respond.

***The IPM may fail to respond to an ON pulse if the preceeding OFF pulse is less than PWIN(off).

Delayed Response Against Shorter Input OFF Signal Than PWIN

(off)

, P-side only

t2

t1

P-SIDE

CONTROL INPUT

INTERNAL

IGBT GATE

OUTPUT

CURRENT IC

Solid Line – OFF Pulse Width > PWIN(off): Turn ON time t1.
Dotted Line – OFF Pulse Width < PWIN(off): Turn ON time t2.

Advertising