PhMKP..., PhMKPg..., Cylindrical, LVAC

www.vishay.com

Vishay ESTA

Revision: 09-Dec-11

3

Document Number: 13004

For technical questions, contact:

[email protected]

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT

ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT

www.vishay.com/doc?91000

CAPACITORS IN CYLINDRICAL CASING

TECHNICAL DATA

STANDARDS

IEC 60831-1 + 2, EN 60831- 1 + 2, UL810 LATEST EDITIONS,
UL/ULC - FILE E97723

Overvoltages
(in accordance with the above standards)

U

cn

+ 10 % (up to 8 h daily)

U

cn

+ 15 % (up to 30 min daily)

U

cn

+ 20 % (up to 5 min, only 200 times in the life of the capacitor)

U

cn

+ 30 % (up to 1 min, only 200 times in the life of the capacitor)

Please also refer to “Terms and Definitions”.

Overcurrent
(in accordance with the above standards)

1.3 x In,
1.5 x In with 10 % overvoltages, 15 % over capacitance and harmonics included,
continuous operation
Please also refer to “Terms and Definitions”.

Tolerance on capacitance

- 5 %/+ 10 % in accordance with the standards
± 5 % as Vishay ESTA standard

Test voltage, terminal/terminal

2.15 x U

cn

, VAC , 2 s (routine test)

Test voltage, terminal/casing

4800 VAC, 2 s (routine test)

Inrush current

300 times rated current I

n

Losses

 0.25 W/kvar to 0.45 W/kvar (without discharge resistors)

Statistical life expectancy

> 150 000 operating h (ESTAprop)
> 130 000 operating h (ESTAdry)

Degree of protection

IP20 clamp terminal with mounted discharge resistor unit or IP00 (terminal cover
for higher protection class upon request), indoor

Ambient temperature category

- 25/D (max. 55 °C) ESTAprop , - 40/D (max. 55 °C) ESTAdry

Permitted casing temperature

Max. 65 °C (measured on top of the can)

Cooling

Naturally air-cooled

Permissible relative humidity

Maximum 95 %

Maximum allowed altitude

2000 m above sea level

Mounting position

Vertical and horizontal

Mounting and grounding

Threaded M12 stud at the bottom of the container

Safety features

All-phase overpressure tear-off fuse, self-healing

Casing

Aluminum can

Dielectric

Polypropylene film, self-healing

Filling agent

Natural oil, non-PCB, biodegradable (ESTAprop) or dry/gas - filled (ESTAdry)

Terminals per casing Ø
(cross-head screws)

Ø 64 mm
IP20 M4 terminal block A (D-351), 3.0 Nm, max. 16 mm

2

drawing 1
max. current, depending on ambient conditions:
34 A (1-phase)/25 A (3-phase)

Ø 84 mm
IP00 M5 screw terminals (D-203), 2.0 Nm, max. 25 mm

2

drawing 2, feed through
max. current, depending on ambient conditions:
57 A (1-phase)/52 A (3-phase)

IP20 M4 terminal block A (D-351), 3.0 Nm, max. 16 mm

2

drawing 3
max. current, depending on ambient conditions:
57 A (1-phase)/52 A (3-phase)

Ø 116 mm
IP20
M5 terminal block B (D-352), 3.0 Nm, max. 25 mm

2

drawing 4
max. current, depending on ambient conditions: 60 A (3-phase)

Ø 136 mm
IP20
M5 terminal block B (D-352), 3.0 Nm, max. 25 mm

2

drawing 5
max. current, depending on ambient conditions: 60 A (3-phase)