Ld47, Pow-r-blok – C&H Technology LD47__50 User Manual

Page 3

Advertising
background image

Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (724) 925-7272

POW-R-BLOK

TM

Dual SCR/Diode Isolated Module

500 Amperes / Up to 1600 Volts

Revision Date: 12/04/2002

LD47__50

Absolute Maximum Ratings

Characteristics Conditions

Symbol

Units

Repetitive Peak Forward and Reverse Blocking
Voltage

V

DRM

& V

RRM

up to 1600

V

Non-Repetitive Peak Blocking Voltage
(t < 5 msec)

V

RSM

V

RRM

+ 100

V

RMS Forward Current

180° Conduction, T

C

=86°C I

T(RMS)

/I

F(RMS)

785

A

Average Forward Current

180° Conduction, T

C

=86°C I

T(AV)

/I

F(AV)

500

A

Peak One Cycle Surge Current, Non-Repetitive

60 Hz, 100% V

RRM

reapplied

50 Hz, 100% V

RRM

reapplied

I

TSM

/I

FSM

I

TSM

/I

FSM

17,000
16,300

A
A

Peak Three Cycle Surge Current, Non-Repetitive

60 Hz, 100%V

RRM

reapplied

I

TSM

/I

FSM

12,250 A

Peak Ten Cycle Surge Current, Non-Repetitive

60 Hz, 100% V

RRM

reapplied

I

TSM

/I

FSM

10,500 A

I

2

t for Fusing for One Cycle

8.3 milliseconds

10 milliseconds

I

2

t

I

2

t

1.20 x 10

6

1.33 x 10

6

A

2

sec

A

2

sec

Maximum Rate-of-Rise of On-State Current,
(Repetitive)

Per JEDEC Standard 397 5.2.2.6

di/dt

200

A/µs

Operating Temperature

T

J

-40

to

+130 °C

Storage Temperature

T

stg

-40

to

+150 °C

Max. Mounting Torque, M6 Mounting Screw

55

6

in. – Lb.

Nm

Max. Mounting Torque, M10 Terminal Screw

110

12

in. – Lb.

Nm

Module Weight, Typical

1500

g

3.30

lb

V Isolation @ 25C

V

rms

3000 V

Advertising