PM50RSD060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
50 Amperes/600 Volts

4

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics,

T

j

= 25

°

C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Over Current Trip Level Inverter Part

OC

T

j

= -20

°

C

220

Amperes

(V

D

= 15V)

T

j

= 25

°

C

109

128

180

Amperes

T

j

= 125

°

C

65

Amperes

Over Current Trip Level Brake Part

OC

-20

°

C

T

j

125

°

C, V

D

= 15V

18

26

Amperes

Short Circuit Trip Level Inverter Part

SC

-20

°

C

T

j

125

°

C, V

D

= 15V

132

Amperes

Short Circuit Trip Level Brake Part

39

Amperes

Over Current Delay Time

t

off(OC)

V

D

= 15V

10

µ

S

Over Temperature Protection (V

D

= 15V)

OT

Trip Level

111

118

125

°

C

(Lower Arm)

OT

R

Reset Level

100

°

C

Supply Circuit Under Voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

(-20

T

j

125

°

C)

UV

R

Reset Level

12.5

Volts

Circuit Current

I

D

V

D

= 15V, V

CIN

= 15V, V

N1

-V

NC

44

60

mA

V

D

= 15V, V

CIN

= 15V, V

XP1

-V

XPC

13

18

mA

Input ON Threshold Voltage

V

CIN(on)

Applied between

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

CIN(off)

U

P

, V

P

, W

P

, U

N

, V

N

, W

N,

B

r

-V

NC

1.7

2.0

2.3

Volts

Fault Output Current*

I

FO(H)

V

D

= 15V, V

CIN

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

CIN

= 15V

10

15

mA

Minimum Fault Output Pulse Width*

t

FO

V

D

= 15V

1.0

1.8

mS

*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower devide operate to protect it.